Home Contact Sitemap login Checkout

S Squared innovations
  • Home
  • Products
    • Products
    • Johnson Controls
      • Johnson Controls
      • S2N2C Gateway
      • S2N2D Gateway
      • S2N2E Gateway
      • S2USB485 Interface
      • S2N2Scan
      • S2485Splitter
      • S2USB485DiagN2
      • S2UI28
    • Building Automation
    • Industrial Converters
    • Lighting Controls
      • Lighting Controls
      • Lighting Projects
        • Lighting Projects
        • High Bay Retro Fit
        • Exterior Down Lighting
        • S2HBwRGBW - High Bay Retrofit Module
        • GE TLC Lighting Controls Upgrade
        • Douglas Lighting Controls MC-6000 Based Replacement
      • S2BACLightDPConfig
      • S2SWDP8
      • S2BACLightDP
  • Services
  • Ordering
  • Clients
  • Company
  • Contact
  • Johnson Controls
    • S2N2C Gateway
    • S2N2D Gateway
    • S2N2E Gateway
    • S2USB485 Interface
    • S2N2Scan
    • S2485Splitter
    • S2USB485DiagN2
    • S2UI28
  • Building Automation
  • Industrial Converters
  • Lighting Controls
Home/Products/Johnson Controls/S2N2D Gateway Print This Page

S2N2D N2 to Douglas Lighting Gateway


This Product has been Obsoleted


For those Douglas Lighting Customers that are looking for a direct replacement/upgrade to the Douglas WRS-2224 Lighting Scanner, then please look at our S2BacLightDP device. 

 

The S2BacLightDP is almost the same size as the Douglas WRS-2224 and maintains the same wiring connections and includes more features (two on-board HVAC compatible inputs, three additional group inputs, Bacnet MS/TP standard, web interface, etc).  Click here to access the S2BacLightDP product page which including a cut sheet.


S2N2D Overview


The S2N2D Gateway bridges the connection between the Johnson Controls N2 Network Bus (N2 Bus) and the Douglas Power WRS-2224 Lighting Scanner Network Bus (DP Bus).  This device allows Douglas Power WRS-2224 Lighting Scanners (with the WR-ASCII Network Module) to be controlled (individual relays and groups/zones) by the Johnson Controls Metasys system.
 
The S2N2D Gateway is connected to both the N2 and DP busses with separate connections to each.  The S2N2D Gateway appears as a slave to the N2 Bus (N2 VND Device), and simultaneously appears as a master to the DP bus.  The actual Douglas Power Lighting Scanners appear as N2 bus slaves to the N2 Bus through the S2N2D gateway.  The N2 Addresses of the DP Scanners are the mapped to the addresses selected on the DP WR-ASCII Network Module.
 
The Douglas Power Scanner’s relays and groups/zones appear as Binary Input and Binary Output objects to the Johnson Controls Metasys system.  The Johnson Controls Metasys Point Map of the system is given in the S2N2D Data Sheet.

Specifications


Part Number:

  • S2N2D-24VAC

Power Requirements:

  • (Standard) 18 - 24 V AC/DC 60 Hz @ 200 mA

Environment:

  • Temperature 0 C to +60 C
  • Humidity: 10 - 95 % RH (non-condensing)

Dimensions:

  • 7.44”L x 3.94”W x 1.75” H 
  • 18.9cm L x 10.0cm W x 4.4cm H

Douglas Support:

  • WRS-2224 with WR-ASCII
  • Maximum of 15 devices
Mounting Options:
  • DIN Rail

N2 Protocol Support

  • Devices mapped as VND
  • N2 Device Objects
  • 24 Relay BIs
  • 5 Group BIs
  • 24 Relay BOs
  • 5 Group BOs

Documents:

  • Data Sheet




S Squared Innovations Inc.

6807-104 Street Edmonton, AB, T6H 2L5

Ph: 1-780-944-1415

info@s2innovations.com


Terms of Use | Privacy Policy | Limited Warranty
Designed by Mediashaker using ShoutCMS